Tianqiong Sensor IOT Technology Co., Ltd
Sales Manager:Ms. Emily Wang
Cel,Whatsapp,Wechat:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China
Sales Manager:Ms. Emily Wang
Cel,Whatsapp,Wechat:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China
Model:FT-QSZ04
Brand:tianqiong
1.Product introduction of Online Multi parameter Water Quality Analyzer
1.Overview
Online Multi parameter Water Quality Analyzer can monitor water quality parameters such as temperature, pH, dissolved oxygen, conductivity, etc.QSZ04 Online Multi parameter Water Quality Analyzer is a comprehensive sensor acquisition, display and analysis system based on Internet of Things technology, and a water quality monitoring micro system.It consists of a steady-flow exhaust unit, an analysis and testing unit, a system control unit and a remote communication unit.It has complete power supply, lightning protection, network communication and other functions.
2.Product Positioning
QSZ04Online Multi parameter Water Quality Analyzer has automatic monitoring function.The main monitoring items of integrated extraction micro water quality automatic monitoring station are: PH, temperature, turbidity, conductivity, dissolved oxygen, COD, ammonia nitrogen, suspended substances, total nitrogen, etc.It uses highly integrated technology to realize automatic water quality monitoring function in one cabinet.
Online Multi parameter Water Quality Analyzer can be widely used in online monitoring of water quality such as rivers, urban or rural water plants, tap water pipe networks, tap water secondary water supply, user endings, indoor swimming pools, large water purification equipment and direct drinking water.It is an indispensable online analysis equipment in the fields of water plant production process control, water conservancy and water management, sanitation supervision, etc.
3.Functions and features
GPRS networking 4G
Supports extended RJ45 networking
Support extended sensor remote transmission
Supports LED screen display 7.0-inch touch control screen
Supports extended Android screen display and storage
Extended Android screen supports 2G data storage and USB data export
Supports RS485 modbus-RTU protocol slaves
Supports multi-channel RS485 modbus-RTU sensor extension
Supporting IoT data display, storage and analysis platforms
The platform supports TCP short links, HTTP protocol and other protocol data forwarding
2.Composition of Online Multi parameter Water Quality Analyzer system
The water supply water quality monitoring micro system consists of a power supply unit, a water pump control unit, an analysis and testing unit, a display unit, a water pump unit, a remote communication unit and an integrated box main unit.
1.Power supply unit
Power supply AC220V.
2.Water pump control unit
The maximum lift of intelligent self-priming pump: 25m opening flow: 1.8m3/h
3.Analysis and testing unit
The analysis and testing unit is mainly composed of pH, dissolved oxygen, conductivity, turbidity, ORP, and temperature sensors.It is fixed to the flow cell by threads or tight fixing parts.The main parameters of the sensor are as follows:
Serial number | Sensor Type | Measurement range | Measurement principle | Measurement accuracy | Configuration |
1 | temperature | 0~50℃ | High-precision digital sensor | ±0.3℃ | √ |
2 | Conductivity | 0~5000uS/cm | Contact electrode method | ± 1.5% | √ |
3 | pH | 0~14 (ph) | Electrochemistry (salt bridge) | ± 0.1PH | √ |
4 | Dissolved oxygen | 0~20mg/L | Fluorescence life method | ± 2% | √ |
5 | Ammonia nitrogen | 0-100.00mg/l | Ion Selection Electrode Method | ±1mg | |
6 | Turbidity | 0~40NTU (select) | Scattering light method | ± 1% | |
7 | COD | 0~500mg/L | UV254 absorption method | ±5% |
Note: The sensor cannot be installed inverted or horizontally when installed, at least tilted above 15 degrees, and the working environment of the above water quality sensor is 0-50℃, <0.3Mpa
4.Display unit
Multi-parameter monitor, installed at the cabinet door, perform data acquisition, analysis, display, communication, and data storage operations.
Android version: 4.4.2·CPU: Quad-core Cortex™-A7·RAM/ROM: 512M/4G·Screen: 7-inch capacitor touch screen·Power supply: 12V/1A·Support USB disk expansion, support memory card expansion
5.Remote communication
RS485 interface MODBUS-RTU communication protocol factory equipment address 6 decimal support 03 function code reading data
6.Equipment box main unit
Installation method | The cabinet floor is installed and the base is installed. |
External dimensions | 1684mm*560mm*510mm 50-100mm adjustable |
Housing material | 216 stainless steel. |
Protection level | IP54 |
powered by | Mains AC220V |
Water inlet | 4 points PE tube |
Water outlet | 6-point water purifier PE tube |
Sewage outlet | 4-point water purifier hose, (can also manually discharge sewage regularly) |
Self-priming pump | Motor power: 200W |
Rated voltage: AC220V/50hz | |
Water pump size 210*145*245/mm | |
Maximum suction range: 8m; maximum lift: 25m | |
Open flow rate: 1.8m3/h | |
Supporting sensor (optional) | PH: 0-14 dissolved oxygen: 0-20mg/L Turbidity: 0-40NTU Conductivity: 0-5000us/cm Temperature: 0°C~50°C |
Wheat seedling conditions are usually classified into strong seedlings, robust seedlings (including first - class and second - class seedlings), and weak seedlings (third - class seedlings). For different seedling conditions, differential management measures need to be taken during key growth stages...
The petrochemical production process involves a large number of flammable and explosive chemical substances, such as crude oil, gasoline, ethylene, and so on. During storage, transportation, and production, these substances can easily trigger explosions and fires once they encounter an ignition sour...
Soil electrical conductivity (EC) is a critical indicator for measuring the content of soluble salts in soil, reflecting the total concentration of various ions in the soil solution or the ionic strength of water-soluble substances. When salts in the soil dissolve, they exist in ionic form—the high...
With the continuous progress of science and technology, refined meteorological monitoring has become an important development direction of modern meteorological services. The purpose of refined meteorological monitoring is to obtain more accurate, detailed, and high spatio-temporal resolution meteor...