Model:FT-CW16H
Brand:tianqiong
fluorescence quantitative PCR instrument basic structure
fluorescence quantitative PCR instrument is a fully automated absolute quantification unit with 4 integrated detection channels that amplifies DNA and measures the fluorescence generated by the amplification.fluorescence quantitative PCR instrument is an instrument that detects reactions in real time, mainly composed of a gene amplification thermal circulation system, a fluorescence real-time detection system, a microcircuit control system, a computer and application software. Two of the core functional modules are: the thermal circulation system and the fluorescence real-time detection system. Among them, the working principle of the gene amplification thermal cycle system is basically the same as that of the traditional gene amplification instrument, and the thermal cycle process is completed by semiconductor heating and refrigeration. The fluorescence detection system mainly consists of fluorescence excitation components, optical signal transmission components, fluorescence detection components, and control systems.
fluorescence quantitative PCR instrument technical indicators
The "///" symbol indicates that the national standard currently does not define this indicator or mandatory requirement.
Metric Name | CW16H | CW32H | CW48H | |
Appearance | ||||
External dimensions | 235mm*385mm*175mm (width*deep*height) | |||
weight | 5.6kg | 5.7kg | 5.8Kg | |
Electrical parameters | ~220V/50Hz, 255W | |||
Data interface | USB 2.0 *2 (two on the right) | |||
Environment parameters | ||||
Running conditions | Temperature: 10-30℃, humidity: 20%~80% | |||
Transportation and storage conditions | Temperature: -20~55℃, humidity: 20%~80% | |||
Altitude | <2500 meters | |||
Noise level | A weight, <60dB | |||
Sample parameters | ||||
Sample capacity | 16*0.2mL | 32*0.2mL | 48*0.2mL | |
Test tube type | Single tube, eight-line test tube | |||
Sample volume | 15-100uL | |||
Temperature characteristics | ||||
Heating/cooling method | Semiconductor heating/refrigeration | |||
Temperature range | 4℃-99℃ | |||
Maximum heating rate | ≥3.5℃/s | |||
Average heating rate | ≥2.5℃/s | |||
Maximum cooling rate | ≥3.5℃/s | |||
Average cooling rate | ≥2.5℃/s | |||
Temperature control accuracy | ≤±0.01℃ | |||
Temperature accuracy | ≤±0.1℃ | |||
Temperature uniformity | ≤±0.3℃ | |||
Optical properties | ||||
Number of fluorescence detection channels | 4 channels | |||
Light emitting devices | High brightness LED | |||
Lighting devices | High sensitivity, high signal-to-noise ratio photodiode | |||
Adapt probe or dye | First channel: 470/520 FAM, SYBR Green | |||
Second channel: 530/570 HEX, JOE, VIC | ||||
Third channel: 580/610 ROX, CY3.5, Texas-Red | ||||
Channel 4: 630/670 CY5 | ||||
Detection sensitivity | 1 copy | |||
Linear detection range | 100~1010 copies | |||
Linear correlation coefficient | ≥0.999 | |||
Channel cross-talk | No cross-talk | |||
Detect repeatability | ≤1.0% |
fluorescence quantitative PCR instrument main application fields
Foodborne pathogenic bacteria detection
Food Safety
Animal and plant origin detection
Plant Science and Agricultural Biotechnology
Gene mutations and polymorphisms
Animal Blight
Basic scientific research
Water monitoring
Pathogen nucleic acid detection
Genetically modified test
Animal epidemic monitoring
Food hygiene quarantine
Customs import and export quarantine
Soil moisture automatic measurement relies on multiple sensor technologies. For soil water content measurement, Frequency Domain Reflectometry (FDR) and Time Domain Reflectometry (TDR) are commonly used. FDR sensors calculate water content by measuring the soil's dielectric constant, as there is...
In today's society, people are paying increasing attention to air quality. As an important component of the air, the measurement of negative oxygen ions is of great significance in many aspects. Firstly, negative oxygen ions can effectively purify the air by combining with particulate matter, ba...
Wind speed monitoring is not only crucial for the promotion of a green lifestyle but also directly affects our daily travel safety and the production environment. When the wind speed is too high, it not only poses a threat to driving safety but may also trigger natural disasters. Therefore, the prec...
Wheat seedling conditions are usually classified into strong seedlings, robust seedlings (including first - class and second - class seedlings), and weak seedlings (third - class seedlings). For different seedling conditions, differential management measures need to be taken during key growth stages...