Tianqiong Sensor IOT Technology Co., Ltd
Sales Manager:Ms. Emily Wang
Cel,Whatsapp,Wechat:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China
Sales Manager:Ms. Emily Wang
Cel,Whatsapp,Wechat:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China
Model:FT-CW32H
Brand:tianqiong
Fluorescent Quantitative PCR Detection System Instrument Basic Structure
Fluorescent Quantitative PCR Detection System is a technology used in a variety of fragment analysis applications to identify and quantify nucleic acids in a variety of biological organisms.Fluorescent Quantitative PCR Detection System is an instrument for real-time detection of reactions. It is mainly composed of a gene amplification thermal circulation system, a fluorescence real-time detection system, a microcircuit control system, a computer and application software. Two of the core functional modules are: the thermal circulation system and the fluorescence real-time detection system. Among them, the working principle of the gene amplification thermal cycle system is basically the same as that of the traditional gene amplification instrument, and the thermal cycle process is completed by semiconductor heating and refrigeration. The fluorescence detection system mainly consists of fluorescence excitation components, optical signal transmission components, fluorescence detection components, and control systems.
Fluorescent Quantitative PCR Detection System Instrument Technical Indicators
The "///" symbol indicates that the national standard currently does not define this indicator or mandatory requirement.
Metric Name | CW16H | CW32H | CW48H | |
Appearance | ||||
External dimensions | 235mm*385mm*175mm (width*deep*height) | |||
weight | 5.6kg | 5.7kg | 5.8Kg | |
Electrical parameters | ~220V/50Hz, 255W | |||
Data interface | USB 2.0 *2 (two on the right) | |||
Environment parameters | ||||
Running conditions | Temperature: 10-30℃, humidity: 20%~80% | |||
Transportation and storage conditions | Temperature: -20~55℃, humidity: 20%~80% | |||
Altitude | <2500 meters | |||
Noise level | A weight, <60dB | |||
Sample parameters | ||||
Sample capacity | 16*0.2mL | 32*0.2mL | 48*0.2mL | |
Test tube type | Single tube, eight-line test tube | |||
Sample volume | 15-100uL | |||
Temperature characteristics | ||||
Heating/cooling method | Semiconductor heating/refrigeration | |||
Temperature range | 4℃-99℃ | |||
Maximum heating rate | ≥3.5℃/s | |||
Average heating rate | ≥2.5℃/s | |||
Maximum cooling rate | ≥3.5℃/s | |||
Average cooling rate | ≥2.5℃/s | |||
Temperature control accuracy | ≤±0.01℃ | |||
Temperature accuracy | ≤±0.1℃ | |||
Temperature uniformity | ≤±0.3℃ | |||
Optical properties | ||||
Number of fluorescence detection channels | 4 channels | |||
Light emitting devices | High brightness LED | |||
Lighting devices | High sensitivity, high signal-to-noise ratio photodiode | |||
Adapt probe or dye | First channel: 470/520 FAM, SYBR Green | |||
Second channel: 530/570 HEX, JOE, VIC | ||||
Third channel: 580/610 ROX, CY3.5, Texas-Red | ||||
Channel 4: 630/670 CY5 | ||||
Detection sensitivity | 1 copy | |||
Linear detection range | 100~1010 copies | |||
Linear correlation coefficient | ≥0.999 | |||
Channel cross-talk | No cross-talk | |||
Detect repeatability | ≤1.0% |
The FT - SQ2A Handheld Weather Station by TianQiong measures wind speed and direction using the ultrasonic time - difference method. It comes with its own display screen, which can display the detected data in real - time. The station is encased in an ABS engineering plastic shell, which is lightwei...
Soil moisture automatic measurement relies on multiple sensor technologies. For soil water content measurement, Frequency Domain Reflectometry (FDR) and Time Domain Reflectometry (TDR) are commonly used. FDR sensors calculate water content by measuring the soil's dielectric constant, as there is...
The Portable el detector is an important device used to detect various defects in photovoltaic (PV) cell modules. It can accurately detect defects such as hidden cracks, fragments, and poor soldering in PV cell modules. These internal defects can seriously affect the service life and long-term power...
Under harsh low - temperature and freezing conditions, anemometers and wind vanes are highly prone to malfunction. As a result, the errors in the collected data increase significantly. Although these devices are equipped with heating units, the units only function on the rotating parts. Once severel...