1.Total Phosphorus Analyzer Principle
Total Phosphorus Analyzer is used to monitor total phosphorus levels, offering a wide measurement range suitable for a variety of wastewater and drinking water applications.Under high temperature and high pressure conditions, the sample is digested with potassium persulfate, and all the phosphorus-containing compounds in the sample are converted into orthophosphate (this step is required to measure orthophosphate).In a 5%-8% nitric acid solution, orthophosphate forms a soluble phosphovana-molybdenum yellow complex with ammonium metavanadate and ammonium molybdate, and its absorbance is measured at a specific wavelength, which is linearly related to the orthophosphate concentration of the sample.In this relation, the absorbance can be converted into the total phosphorus (TP) or orthophosphate (PO4) concentration value of the sample.
2.Total Phosphorus Analyzer product features
The new optoelectronic quantitative technology is not affected by interference such as large chromaticity, many suspended objects, and many bubbles.It has high reliability and accuracy and strong anti-interference ability.
High detection accuracy, low measurement limit, and low long-term drift of the instrument.
It has one-click self-test function and self-diagnosis function.
It adopts a single-channel high-integrated valve set, making maintenance and cleaning simple and fast.
All-weather networking function, monitoring the operating status of the instrument anytime and anywhere.
It has alarm function, quality control function and counter control function.
It has automatic cleaning function and automatic calibration function.
It has full-point measurement, interval measurement and external control measurement.
It works automatically after power failure recovery.
Automatic prompts and automatic reset functions for faults and reagents (samples).
It has fault logging function.
Can save historical data for more than 3 years.
Satisfies the separation of cleaning liquid and waste liquid
3.Technical parameters of Total Phosphorus Analyzer
Measurement method: ammonium molybdate spectrophotometry (HJ670-2013)
Measuring range: 0-2 mg/L; 0-10 mg/L; 0-50 mg/L; range can be customized
Display error: ≤±3% detection limit: 0.010mg/L
Repeatability: ≤±3% Waste liquid volume: 4.5mL/time
Memory effect: ≤±1%Real water sample comparison: ±8%
Constant temperature time: 900 seconds Voltage stability: ≤±5%
Measurement cycle: 39 minutes Calibration cycle: any specified time
Maintenance cycle: ≥720h/time Maintenance workload: <2 hours/month
Reagent consumption: 3 months/500ml display output: configured with a 10.1-inch color LCD touch screen
Color rendering temperature: The recommended temperature is 120℃, which can be set according to the actual water sample condition
Data export: The measured value can be imported into the USB drive and saved in the USB drive.
Signal output: RS485/RS232/USB interface/standard 2-channel 4-20mA output/standard two-channel switching input and output
Environmental requirements: Indoors with controllable temperature, recommended temperature (5-28℃), humidity ≦90% (no condensation)
Power supply and power: (220V±22) V/AC, (50±0.5Hz), 5A, 150W
Instrument size: upper cabinet 600*450*300mm; upper cabinet 700*450*300mm
In the field of meteorological monitoring, traditional monitoring methods have limitations in specific geographical environments. Ground-based equipment is restricted by terrain and difficult to achieve comprehensive coverage; while satellites can provide macro-level monitoring, they lack precision...
Gridization is a technical means that divides the geographical space into several regular or irregular grid units. Through independent monitoring, analysis, and management of each grid, it achieves refined management of the entire region. In the field of environmental monitoring, grid-based manageme...
The Portable IV Curve Tester is known as the "stethoscope" of power stations, capable of accurately diagnosing the operational status of power stations.The working principle of the Portable IV Curve Tester is based on the photovoltaic effect and basic circuit principles. When light shines...
In tourist attractions, air quality is one of the important factors attracting visitors. As a key indicator for measuring air quality, negative oxygen ion concentration has received increasing attention from more and more scenic spots. Known as the "vitamin of the air," negative oxygen ion...