Model:FT-YDQ1
Brand:tianqiong
Toxic gas detector product introduction
Toxic gas detector provides workers with a convenient way to detect toxic and corrosive gases such as carbon monoxide, nitrogen dioxide, etc. at the palm of their hands.Toxic gas detector is suitable for measuring and alarming the concentration of carbon monoxide, oxygen, and nitrogen dioxide gas in underground operating environments of coal mines. It has functions such as date, time, sound and light alarm. The measuring device has the advantages of simple operation, easy portability, accurate and reliable.
a. Temperature: 0℃~+40℃
b. Relative humidity: ≤98% (+25℃)
c. Atmospheric pressure: 80~110kPa
d. Wind speed: ≤8m/s
e. No significant vibration or impact
f. In dangerous places with explosive gas mixtures.
| Measure gas | Carbon monoxide, oxygen, nitrogen dioxide |
| Measurement principle | Electrochemical principles (CO, O2, NO2) |
| Measurement range | CO:(0~1000)×10-6 O2:(0.0~25.0)% NO2:(0.0~100)×10-6 |
| Basic error | CO:(0~20)×10-6:±2×10-6 (20~100)×10-6:±4×10-6 (100~500):True value±5% (500~1000):True value±6% O₂(0.0~5.0)% O₂:±5% O₂ (>5.0~25.0)% O₂:±3% O₂ FS NO₂:(0~20.0)×10-6:±2.5×10-6 |
| Alarm point and error | The alarm value can be set at will, the following is the default alarm value CO:Alarm point24×10-6,Alarm error±1×10-6 O₂:Alarm point18.0%,Alarm error±0.3%O₂ NO₂:Alarm point5.0×10-6,Alarm error±1×10-6 |
| Response time | CO: No more than 45 seconds O₂: No more than 35 seconds NO₂: No more than 45 seconds |
| Alarm sound level intensity | Not less than 80dB (1 meter away from the buzzer) |
| Light alarm intensity | Not less than 20 meters (dark) |
| Sensor life | 1 year |
| Continuous battery working time | >12 hours (non-alarm status) |
| Appearance and size | 127mm×67mmx43mm/500g |
| Explosion-proof form | Intrinsic security for mining |
Wheat seedling conditions are usually classified into strong seedlings, robust seedlings (including first - class and second - class seedlings), and weak seedlings (third - class seedlings). For different seedling conditions, differential management measures need to be taken during key growth stages...
Meteorological Instruments for Solar Energy is a professional device that integrates the monitoring functions of six key meteorological parameters: temperature, humidity, wind speed, wind direction, air pressure, and rainfall. Its core highlight lies in its highly integrated and ingenious design. It...
EL (Electroluminescence) detection, a non-destructive testing method, works as follows: When a forward bias is applied to a photovoltaic (PV) module, electrons and holes diffuse to the P and N regions, respectively. The radiative recombination of charge carriers generates photons, resulting in the e...
A cleanroom is a sealed space where parameters such as air cleanliness, temperature, humidity, and pressure are strictly controlled. It is widely used in industries with harsh environmental requirements, such as electronics, pharmaceuticals, healthcare, and biotechnology. Through special air purific...