Tianqiong Sensor IOT Technology Co., Ltd
Sales Manager:Ms. Emily Wang
Cel,Whatsapp,Wechat:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China
Sales Manager:Ms. Emily Wang
Cel,Whatsapp,Wechat:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China
Model:FT-SS11S
Brand:tianqiong
1.Introduction to Portable sludge concentration analyzer
Portable sludge concentration analyzer is an essential tool for accurately measuring sludge levels in wastewater treatment processes using the scattered light method.SS11S model Portable sludge concentration analyzer is an electrode method water quality analysis instrument that uses all digital electrode detection to detect sludge concentration parameters of water quality.The instrument is equipped with a self-developed FTIOT operating system, which has simple operation, stable performance, accurate measurement, wide detection range, and has a built-in high-capacity rechargeable lithium battery, which is convenient for users to conduct water quality inspection at any time in the field and in the laboratory.
2.Portable sludge concentration analyzer host parameters
Charging input voltage | 4.5V-5.5V |
Charging current | <2A |
Screen size | 3.5 inches |
Screen resolution | 480*800☆ |
Screen interface | MIPI DSI☆ |
USB port | 2 (Support external expansion of mouse, keyboard, 4G, etc.)☆ |
Type-C | 1 (Support external expansion of mouse, keyboard, 4G, etc.)☆ |
RS485 | 2 (Support Modbus, json, asc input, etc.) |
External sensor power supply voltage | 12V |
External sensor power supply current | 1A |
operating system | ftiot (based on Linux-5.4)☆ |
CPU | 2*Cotex-A7, 650Mhz☆ |
RAM | 512M DDR3☆ |
Flash | 8G-64G |
OpenGL | ES 2.0☆ |
Wifi | support |
4G | Selection |
button | support |
Capacitive touch screen | support |
Software Architecture | B/S☆ |
Web access | Support ☆ |
MTP mode | Support ☆ |
Multi-terminal login | Support ☆ |
IPV6 | Support ☆ |
Sensor communication method | RS485, TCP, UDP, Http☆ |
Data forwarding method | RS485, TCP, UDP, Http☆ |
Remote SSH | Support ☆ |
Remote debugging | Support ☆ |
3.Portable sludge concentration analyzer sensor parameters and configuration
Serial number | name | Measurement range | principle | Measurement accuracy | Configuration | Remark |
1 | temperature | 0~50℃ | High-precision digital sensor | ±0.3℃ | ||
2 | pH | 0~14 (ph) | Electrochemistry (salt bridge) | ±0.1PH | ||
3 | ORP | -1500mv~1500mv | Electrochemistry (salt bridge) | ±6mv | ||
4 | Conductivity | 0~5000uS/cm, 0~10000uS/cm | Contact electrode method | ±1.5% | ||
5 | TDS | 0~20μS/cm (TDS 0-10mg/L) | Contact electrode method | ±1.5% | ||
6 | salinity | 0-2.5ppt or 0-80ppt | Contact electrode method | ±0.05ppt or ±1ppt | ||
7 | Sludge concentration | 0~20.000g/L | Scattering light method | ±5% (depending on sludge homogeneity) | ✔ | |
8 | Turbidity | 0~40NTU (low turbidity) | Scattering light method | ±1% | Optional | |
0~1000NTU (medium turbidity) | Scattering light method | ±1% | ||||
0~3000NTU (high turbidity) | Scattering light method | ±1% | ||||
9 | Dissolved oxygen | 0~20mg/L | Fluorescence life method | ±2% | ||
10 | Ammonia nitrogen | 0~100mg/l | Ion Selection Electrode Method | ±1mg | ||
11 | Suspension | 0~2000mg/L | Scattering light method | ±5% (depending on sludge homogeneity) | ||
12 | Residual chlorine | 0~5.00mg/L | Ion Selection Electrode Method | ±5% of reading | The best accuracy is when the flow rate is 0.42m/s-0.85m/s | |
13 | Chloride ions | 0-3500.0mg/L | Ion Selection Electrode Method | ±5% | ||
14 | Total hardness | 0~1000.0mg/L | Ion Selection Electrode Method | ±10% of reading | ||
15 | cod | 0~500mg/L | UV254 absorption method | ±5% | COD and chlorophyll have automatic cleaners, which can prevent biological adhesion and avoid light window pollution, so as to ensure that long-term monitoring is still stable; automatic cleaning time and cleaning times can be set, and the power consumption is 0.7W | |
16 | Chlorophyll | 0~400ug/L | Fluorescence method | R2>0.999 |
In the fields of solar energy resource assessment and meteorological monitoring, the Fully Automatic Solar Spectrometer is revolutionizing traditional measurement methods. This instrument combines multi - spectral filters with thermopiles to capture radiant energy within the spectral range of 280 to...
With the increasing demand for ecological protection and sustainable development in modern agriculture, the environmental pollution and pest resistance caused by the overuse of traditional chemical pesticides urgently need to be addressed. Physical pest control methods have gradually become an impor...
In the modern industrial field, the chemical industry has an extremely high demand for meteorological monitoring. The chemical production process is complex and involves many flammable, explosive, and corrosive chemical substances. For example, in a chemical industrial park, under different meteorol...
Meteorology encompasses a wide range of elements, such as rain, ice, wind, frost, clouds, and temperature, among others. In the power system, "micro-meteorology" is different from what is described in meteorology. Power micro-meteorology refers to the meteorological conditions in a small s...