Tianqiong Sensor IOT Technology Co., Ltd
Sales Manager:Ms. Emily Wang
Cel,Whatsapp,Wechat:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China

Sales Manager:Ms. Emily Wang
Cel,Whatsapp,Wechat:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China

Model:ADCP-1
Brand:tianqiong
1、Acoustic Doppler Current Profiler Product Introduction
Acoustic Doppler Current Profiler measures the velocity and direction of water flow throughout a water column by emitting acoustic pulses and analyzing the Doppler shift of the signal.Acoustic Doppler Current Profiler is a brand new River ADCP device independently developed, manufactured, and sold by our company.
Acoustic Doppler Current Profiler is equipped with a 600kHz acoustic transducer, employing a Janus four-beam design with a vertical beam, a lightweight POM structure, low power consumption, and convenient installation and deployment. Its performance is comparable to top international ADCP products, and it is specifically designed for hydrological flow monitoring scenarios such as inland rivers, canals, and reservoirs.
2、Acoustic Doppler Current Profiler Product Advantages
Domestic Substitution: The product is comparable to top international ADCP products and can directly replace them.
High Precision: Precision comparable to top international products.
High Reliability: Continuous operating time of at least 100 days.
Small Size: Significantly smaller than comparable international products.
Strong Compatibility: Compatible with similar product protocols.
Easy Operation: Can operate upon power-on/can be set to automatic operation.
High Cost-Effectiveness: Performance comparable to comparable international products, with a more competitive price.
3、Acoustic Doppler Current Profiler Application Scenarios
River flow monitoring, ecological flow forecasting, irrigation canal water volume monitoring, reservoir inflow and outflow observation, urban river water environment monitoring, hydrological emergency patrols
4、Acoustic Doppler Current Profiler Technical parameters
| Composition | Technical Specifications | Parameters |
| Flow rate measurement | Operation Mode | Broadband/Pulse Correlation |
| Profile scope | 0.54-40m | |
| Flow measurement accuracy (typical) | ±0.25%±2mm/s | |
| Flow rate resolution | 1mm/s | |
| Speed test range | ±5.0m/s (default); ±20.0m/s (maximum) | |
| Flow measurement range | 0-360° | |
| Flow measurement accuracy | ±2° | |
| Number of units | 1-255 | |
| Unit layer thickness | 0.1-5m² | |
| Data output rate | 1-2Hz (typical value) | |
| Bottom tracking | Operation Mode | Broadband |
| Speed test range | ±10m/s | |
| Depth Range | 0.54-110m | |
| Measurement accuracy | ±0.25%±2mm/s | |
| Resolution | 1mm/s | |
| Deep Measurement | Measurement Range | 0.54-110m |
| Measurement accuracy | ±1% | |
| Resolution | 1mm | |
| Transducer and Hardware | Frequency | 600kHz |
| Configuration | 4 active piezoelectric transducers, Janus arrangement; 1 vertical piezoelectric transducer | |
| Beam angle | 20° | |
| Internal storage | 64GB | |
| Communication | Communication Interface | RS-232 (baud rate: 1200-115200) or RS-422 |
| Standard Sensor | Temperature sensor | Range: -5℃ to 45℃; Accuracy: ±0.5℃ |
| Pressure sensor | Range: Determined by the depth rating; Accuracy: ±0.25%; Resolution: 1mm | |
| Attitude sensor (roll and pitch) | Range: ±90°; Accuracy (RMS): ±0.3° | |
| Compass sensor | Range: 0-360°; Accuracy (RMS): ±1° | |
| GPS (Embedded) | 3m level | |
| Power supply | Power supply interface | 10-26V |
| Average power consumption | ≤5W | |
| Structure | Casing material | POM |
| Environment | Operating temperature | -5℃-45℃ |
| Storage temperature | -40℃-70℃ | |
| Physical properties | Pressure depth | 50m |
| Weight (in air) | ≤2.5kg | |
| Size | Φ176mm×194mm |
This instrument integrates FDR (Frequency Domain Reflectometry) principle soil moisture measurement sensors and data acquisition technology. Through moisture and temperature sensors, it accurately measures soil volumetric water content (VWC) and temperature. Powered by solar energy, it is adap...
Water quality micro monitoring station is a miniaturized, integrated, and intelligent online water quality monitoring system. This device integrates five measurement modules—total phosphorus, total nitrogen, chemical oxygen demand, permanganate index, and ammonia nitrogen—as well as conventi...
Negative oxygen ions exert physiological effects on the human nervous system and blood circulation. Their concentration directly reflects air quality and serves as a key indicator for air quality assessment. The Negative Oxygen Ion Monitoring Station is specially designed to monitor this core indica...
The weather stations used in the agricultural field are called Agricultural Weather Stations. In order to better serve agricultural production, in addition to the conventional meteorological elements, Agricultural Weather Stations will also focus on increasing the monitoring of soil-related elements...