Tianqiong Sensor IOT Technology Co., Ltd
Sales Manager:Ms. Emily Wang
Cel,Whatsapp,Wechat:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China

Sales Manager:Ms. Emily Wang
Cel,Whatsapp,Wechat:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China

Model:FT-CW48H
Brand:tianqiong
Basic structure of African Swine Fever Virus instrument
African Swine Fever Virus is a highly contagious viral disease of domestic and wild swine that causes hemorrhagic fever with high mortality in domestic pigs.African Swine Fever Virus is a real-time reaction detection instrument, mainly composed of a gene amplification thermal circulation system, a fluorescence real-time detection system, a microcircuit control system, a computer and application software. Two of the core functional modules are: the thermal circulation system and the fluorescence real-time detection system. Among them, the working principle of the gene amplification thermal cycle system is basically the same as that of the traditional gene amplification instrument, and the thermal cycle process is completed by semiconductor heating and refrigeration. The fluorescence detection system mainly consists of fluorescence excitation components, optical signal transmission components, fluorescence detection components, and control systems.
African Swine Fever Virus Instrument Technical Indicators
The "///" symbol indicates that the national standard currently does not define this indicator or mandatory requirement.
| Metric Name | CW16H | CW32H | CW48H | |
| Appearance | ||||
| External dimensions | 235mm*385mm*175mm (width*deep*height) | |||
| weight | 5.6kg | 5.7kg | 5.8Kg | |
| Electrical parameters | ~220V/50Hz, 255W | |||
| Data interface | USB 2.0 *2 (two on the right) | |||
| Environment parameters | ||||
| Running conditions | Temperature: 10-30℃, humidity: 20%~80% | |||
| Transportation and storage conditions | Temperature: -20~55℃, humidity: 20%~80% | |||
| Altitude | <2500 meters | |||
| Noise level | A weight, <60dB | |||
| Sample parameters | ||||
| Sample capacity | 16*0.2mL | 32*0.2mL | 48*0.2mL | |
| Test tube type | Single tube, eight-line test tube | |||
| Sample volume | 15-100uL | |||
| Temperature characteristics | ||||
| Heating/cooling method | Semiconductor heating/refrigeration | |||
| Temperature range | 4℃-99℃ | |||
| Maximum heating rate | ≥3.5℃/s | |||
| Average heating rate | ≥2.5℃/s | |||
| Maximum cooling rate | ≥3.5℃/s | |||
| Average cooling rate | ≥2.5℃/s | |||
| Temperature control accuracy | ≤±0.01℃ | |||
| Temperature accuracy | ≤±0.1℃ | |||
| Temperature uniformity | ≤±0.3℃ | |||
| Optical properties | ||||
| Number of fluorescence detection channels | 4 channels | |||
| Light emitting devices | High brightness LED | |||
| Lighting devices | High sensitivity, high signal-to-noise ratio photodiode | |||
| Adapt probe or dye | First channel: 470/520 FAM, SYBR Green | |||
| Second channel: 530/570 HEX, JOE, VIC | ||||
| Third channel: 580/610 ROX, CY3.5, Texas-Red | ||||
| Channel 4: 630/670 CY5 | ||||
| Detection sensitivity | 1 copy | |||
| Linear detection range | 100~1010 copies | |||
| Linear correlation coefficient | ≥0.999 | |||
| Channel cross-talk | No cross-talk | |||
| Detect repeatability | ≤1.0% | |||
Major application areas of African Swine Fever Virus instruments
Foodborne pathogenic bacteria detection
Food Safety
Animal and plant origin detection
Plant Science and Agricultural Biotechnology
Gene mutations and polymorphisms
Animal Blight
Basic scientific research
Water monitoring
Pathogen nucleic acid detection
Genetically modified test
Animal epidemic monitoring
Food hygiene quarantine
Customs import and export quarantine
The Portable Weather Station enhances monitoring convenience and efficiency with its lightweight, integrated design, meeting the demand for rapid and accurate acquisition of meteorological data across multiple fields.The core of achieving the lightweight and integrated design of such devices lies in...
Under harsh low - temperature and freezing conditions, anemometers and wind vanes are highly prone to malfunction. As a result, the errors in the collected data increase significantly. Although these devices are equipped with heating units, the units only function on the rotating parts. Once severel...
Meteorology encompasses a wide range of elements, such as rain, ice, wind, frost, clouds, and temperature, among others. In the power system, "micro-meteorology" is different from what is described in meteorology. Power micro-meteorology refers to the meteorological conditions in a small s...
Water quality monitoring micro-station is a new type of online monitoring product for environmental protection and water conservancy fields. It can real-time monitor parameters such as dissolved oxygen, turbidity, and pH in rivers, lakes, and reservoirs, and features automatic monitoring and data uploading functions, meeting the needs of high-density deployment....