Model:FT-WS10
Brand:tianqiong
1.Product introduction of Waste Water Quality Monitoring
Waste Water Quality Monitoring includes measuring temperature, pH, conductivity (salinity) and turbidity, etc., providing data and information for environmental management.WS10 Online Waste Water Quality Monitoring is an instrument that can monitor water temperature, COD, ammonia nitrogen, ph, residual chlorine, dissolved oxygen, conductivity, turbidity, orp online.It integrates the corresponding sensor and measurement module communication storage, and can quickly and accurately record key parameters in the water body.At the same time, the instrument supports extended water quality multi-parameter sensors, including but not limited to pH, dissolved oxygen (DO), conductivity, turbidity, temperature, ammonia nitrogen, etc., which can be combined and configured according to different needs and applications, record and store historical monitoring data and alarm history records, and support the export of historical data.xlsx.The RS485 interface supports MODBUS-RTU communication protocol to facilitate users to communicate freely with PLC, DCS, configuration software, DTU and other devices to connect and transmit data.
2.Waste Water Quality Monitoring Application Field
Online Waste Water Quality Monitoring is widely used in the monitoring and control of various water bodies, including but not limited to the following areas:
1.Water plant: used to monitor the pH value, dissolved oxygen, turbidity and other parameters of tap water to ensure the safety and hygiene of tap water.
2.Groundwater monitoring: used to monitor the pH, conductivity, temperature and other parameters of groundwater in order to promptly discover and solve water quality problems.
3.River and lake monitoring: used to monitor the water quality of rivers and lakes, such as dissolved oxygen, turbidity, ammonia nitrogen and other parameters, so as to take pollution control measures in a timely manner.
4.Ocean monitoring: used to monitor the ocean's water quality, such as salinity, dissolved oxygen, temperature and other parameters, so as to promptly detect and control marine pollution.
5.Sewage treatment: used to monitor the water quality parameters of sewage, such as pH, COD, ammonia nitrogen, etc., in order to control and regulate the sewage treatment process.
6.Industrial production: used to monitor the water quality conditions in the industrial production process, such as pH, conductivity, dissolved oxygen and other parameters, so as to adjust the process process in a timely manner and ensure product quality.
7.Scientific research: used for water quality monitoring in the field of scientific research, such as lake eutrophication, climate change and other research.
3.Waste Water Quality Monitoring technical features
1.High reliability: suitable for long-term working in the wild environment, stable measurement and strong anti-interference ability.
2.Flexible and portable: Each probe can be freely combined, replaced independently, and used for plug and play.
3.Scalability: Freely combine multiple sensors.
4.Multiple applications: rapid on-site measurement, emergency monitoring, or long-term online monitoring of groundwater, river water, lake water sources, and urban pipeline water.
5.Tough shell: ABS+PC material, corrosion-resistant, can work normally for a long time.
6.Compact structure: can be installed in smaller sizes.
7.Communication connection: RS485 extended interface, master/slave interface isolation can communicate independently.
4.Waste Water Quality Monitoring Technical Parameters
| Display output | 4.3-inch touch screen with LED strong backlight, can be operated under direct sunlight | 
| power supply | DC power supply: DC12V | 
| Power consumption | The instrument power consumption is about 12V/1W | 
| Sound output | buzzer | 
| Communication protocol | Standard RS485 Modbus-RTU protocol and device master/slave transmission channel support | 
| Main materials | ABS+PC material | 
| Storage temperature | -20 to 70℃ | 
| Operating temperature | -10 to 50℃ | 
| Protection level | IP65 | 
| size | 175mm*140mm*49mm(Length×Width×Height) | 
| weight | About 0.5KG | 
5.Waste Water Quality Monitoring sensor configuration (optional)
| Serial number | name | Measurement range | principle | Measurement accuracy | Configuration | Remark | 
| 1 | temperature | 0~50℃ | High-precision digital sensor | ±0.3℃ | ✔ | |
| 2 | pH | 0~14 (ph) | Electrochemistry (salt bridge) | ± 0.1PH | ✔ | |
| 3 | ORP | -1500mv~1500mv | Electrochemistry (salt bridge) | ± 6mv | ✔ | |
| 4 | Conductivity | 0~5000uS/cm | Contact electrode method | ± 1.5% | ✔ | |
| 5 | Turbidity | 0~40NTU (low turbidity) | Scattering light method | ± 1% | Optional | |
| 0~1000NTU (medium turbidity) | Scattering light method | ± 1% | ||||
| 0~3000NTU (high turbidity) | Scattering light method | ± 1% | ✔ | |||
| 6 | Dissolved oxygen | 0~20mg/L | Fluorescence life method | ± 2% | ✔ | |
| 7 | Ammonia nitrogen | 0-1000.00mg/L (default) 0-100.00mg/l/ (customizable) | Ion Selection Electrode Method | 10% of reading, ±0.5℃ | ✔ | |
| 8 | Suspension | 0~2000mg/L | Scattering light method | ±5% (depending on sludge homogeneity) | ||
| 9 | Residual chlorine | 0~5.00 mg/L | Ion Selection Electrode Method | ±5% of reading | ✔ | |
| 10 | Chloride ions | 0-3500.0mg/L | Ion Selection Electrode Method | ±5% | ||
| 11 | Total hardness | 0~1000.0mg/L | Ion Selection Electrode Method | ±10% of reading | ||
| 12 | cod | 0~500mg/ L | UV254 absorption method | ±5% | ✔ | COD and chlorophyll have automatic cleaners, which can prevent biological adhesion and avoid light window pollution, so as to ensure that long-term monitoring is still stable; automatic cleaning time and cleaning times can be set, and the power consumption is 0.7W | 
| 13 | Chlorophyll | 0~400ug/L | Fluorescence method | R2>0.999 | 
The FT-WQX6 micro weather sensor is a highly integrated device that combines multiple meteorological parameter measurement functions. Its key feature is the integration of six basic meteorological parameters—ambient temperature, relative humidity, wind speed, wind direction, atmospheric pressure, a...
The Photovoltaic Weather Station under Tianqiong enables precise, real-time, and continuous monitoring. Specifically designed for the photovoltaic industry, it accurately detects key meteorological parameters that affect photovoltaic power generation. In particular, regarding solar radiation, it can...
Negative oxygen ions exert physiological effects on the human nervous system and blood circulation. Their concentration directly reflects air quality and serves as a key indicator for air quality assessment. The Negative Oxygen Ion Monitoring Station is specially designed to monitor this core indica...
Under harsh low - temperature and freezing conditions, anemometers and wind vanes are highly prone to malfunction. As a result, the errors in the collected data increase significantly. Although these devices are equipped with heating units, the units only function on the rotating parts. Once severel...